High Pressure TurboDrop® NOZZLE:
• Optimal pressure range is 40-120 psi. Targeting 80 psi operating
pressure will allow for greater changes in speed and pressure. Max pressure
is 150 psi.
• Between 30 and 80 psi, the spray angle of the exit tip will narrow by approximately 10-15% (making a 110° degree tip essentially a 90-100° tip). Make necessary boom heighth adjustment for desired overlap. (For 20" spacing, a height of 24-40" is recommended.)
• Higher
pressures (60-150psi) are recommended for penetration into a dense crop
canopy and for better coverage with contact chemicals.

High Pressure TurboDrop® VENTURI:
• The venturi must be correctly
matched to the exit tip. The venturi controls the flow rate; the exit tip
determines the pattern only.
• Flat fan, flood, twin spray, hollowcone tips and others may
be used with the venturi. Droplet size will vary with type of exit tip
used. (Please consult Greenleaf Technologies.)
• Certain exit tips require the use of a diffuser (part#DIF4)
and Greenleaf Cap.
• Always test any combination that you intend to use.
|